Search by Tags

WEC T20 / T30 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the Tegra Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version (e.g. V1.3beta1) will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

Not Planned
WC-1774Known IssueUART RX events are signaled only onceColibri T20, Colibri T30, Apalis T30UARTCE6, WEC7, WEC2013

Description: Currently the UART driver triggers RX events only once. If the event is not handled by the application and the data is not read, there will not be signaled any other RX event, also not if new data arrives on the device. Trigger a manual read data to reenable the RX events.

Workaround: Make sure you do not miss any RX event. If not possible, set a timeout after which you will manually trigger a manual read.