Issue #StatusSubjectModuleSubsystemWinCE OS

Not Planned
WC-2099Known IssueModule does not boot when not using default debug serial port on T30Colibri T30BootloaderCE6, WEC7

Description: On the Apalis or Colibri T30 when using an other debug (ser.port) output then the default one (Port 1) the system does not boot.

Workaround: This issue can be fixed by disabling the serial port you set in the bootloader ser.port bootloader configuration (see http://developer.toradex.com/knowledge-base/disable-drivers)