Search by Tags

WEC T20 / T30 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the Tegra Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version (e.g. V1.3beta1) will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

2.2b4 (Release date: 2018-09-17)
- WinCE 6 Updates: Installed Updates until 2018M03
- WEC 7 Updates: Installed Updates until 2018M06
- WEC 2013 Updates: Installed Updates until 2018M07
WC-1817FixedLVDS Converter Freezes After Switching From Splashscreen to WinCE DesktopColibri T20, Colibri T30LVDSCE6, WEC7

Description: In some cases LVDS signals are not toggling any longer after switching from splash screen to the main WinCE desktop. This is due to some problems in the LVDS converter chip. Fixed by not disable/enable display controller between splashscreen and windows ce desktop. NOTE: This can only be done if the Splashscreen resolution matches the desktop resolution. In that case the complete display timings will stay as configured in Splashscreen. To revert to previous behavior set "UseSplashSettings"=0 [HKLM\SOFTWARE\NVIDIA Corporation\NVDDI]

Workaround: Either disable the splash screen or toggle backlight pin in a user space application, to disable/enable the LVDS converter.