Search by Tags

WEC PXA BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the PXA Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

V4.5 (Release date: 2015-06-19)
- WinCE 5 Updates: Installed Microsoft CE5 Updates until 2014M07
- WinCE 6 Updates: Installed Microsoft CE6 Updates until 2014M07
WC-1217FixedMAC Address and HW Version get overwritten by the UpdateTool in BSP V4.4 on Colibri PXA3xx modulesColibri PXA320, Colibri PXA310, Colibri PXA300 XT, Colibri PXA300ConfigBlockCE5, CE6

Description: A bug in Kernel V4.4 leads to overwritten MAC address and hardware version settings in the config block when using the UpdateTool to restore the config block. This is normally done, if you use a complete Flash backup to clone the Colibri module SW configuration in production process. Having modules with the same MAC address is only a problem if you are using these devices in the same Ethernet network.

Workaround: The following article describes the problem in detail and provides various solutions: http://developer.toradex.com/knowledge-base/colibri-pxa3xx-bsp-v4-4-update-tool-issue